• Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
  • Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
  • Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
  • Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
  • Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
  • Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W

Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W

Regenerative Type: Electricity Type
Electrolyte: Pemfc
Working Temperature: <100°c
Fuel Type: Hydrogen Oxygen Fuel Cell
Indirect Type: Other
Generation: Other
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
T-ALFR-50W
Solutions
Other
Rated Voltage
5.5V
Rated Current
9.1A
Diameter of Gas Tube
6 mm
Pole Ear Aperture
6 mm
Transport Package
Single
Specification
50W
Trademark
Thinkru
Origin
China

Product Description

Product Description:
50W Oxyhydrogen High-Temperature Fuel Cell

Product specifications:
Rated voltage: 5.5 V
Rated current: 9.1 A
Starting temperature: ≥ 100 ºC
Working temperature: ≈ 160 ºC
Rated power theoretical hydrogen consumption: 0.635 L / min, metering ratio 3 ~ 4.
Rated power theoretical air consumption: 1.5 L / min, metering ratio 40 ~ 50.
External heating power demand 3 kw.


Interface:
Diameter of gas tube:6 mm
Pole ear aperture: 6 mm


Material:
End plate material, aluminum alloy plate material, graphite, copper lug, microporous proton exchange membrane, carbon paper, gas diffusion and the conductive layer, platinum catalyst, etc.
Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
Precautions and risk notification:
1. Oxyhydrogen fuel cell stack has high operation requirements and a dangerous gas environment. Users using this product should have sufficient experimental knowledge and skills and professional equipment site (including stack air tightness test conditions) and operate safely and normally in the professional site environment, otherwise, it may cause various degrees of damage to the stack or even a wider range of property and life safety damage.
2. The operation of this product requires hydrogen, compressed air, and nitrogen. When using this product, we should pay strict attention to the safety of gas use and avoid hydrogen accumulation and nitrogen concentration, otherwise it may cause hydrogen deflagration, nitrogen suffocation, compressed gas safety events, and other consequences.
3. This product should be kept away from an open fire.
4. This product should be handled with care, and avoid internal contact with impure water and impurity-rich air, otherwise it may cause physical or chemical damage to the stack.
5. Do not disassemble the stack without the guidance of a professional stack engineer, otherwise, it may cause damage to the stack. At the same time, in addition to sending it to our company (see *) for repair, our company will not be responsible for product damage or even wider damage caused by any form of disassembly.
6. Before each use of the product, the user should pay attention to observe the product state and confirm whether the product has air tightness damage, etc. If the product has air tightness damage, the use plan of the stack shall be terminated immediately, otherwise, it may cause different degrees of damage or even wider damage to the stack.
7. When using this product, the gas shall be introduced in strict accordance with the fuel cell specifications. Specific information such as the type, pressure, and environment of the introduced gas can be obtained from our company, and our company promises to provide the use specification information unconditionally. If the stack is not used in a standardized way, it may cause various degrees of damage to the stack or even a wider range of damage.
8. During the operation of the reactor, sudden start-up, and shutdown, lack of gas at the anode and cathode or abnormal fluctuation of air pressure shall be avoided. After the operation of the reactor is stopped, attention shall be paid to purging the remaining electricity with nitrogen, otherwise it may cause damage such as voltage reversal of the reactor and perforation of the proton exchange membrane, and may cause fatal damage to the reactor.


Precautions and risk notification:
1. The product power, rated voltage, and materials may change due to the negotiation and customization between the buyer and our company. When the buyer and our company reach an agreement, the negotiation information shall prevail.
2. This document is only for the buyer and user to obtain necessary product information and risk information. The buyer and user shall not transfer this document beyond the authority of the buyer and user.
3. The sales information of this product is subject to the sales order or sales contract.
4. The rated voltage and current of this product are theoretical values, which will inevitably be affected by the operating environment.
5. The size of this product may have a very small range (≤ 1mm) processing error.

Hot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50WHot Selling Power Hydrogen-Oxygen High-Temperature Fuel Cell Stack 50W
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now