Product Description
Technical parameters of electrostatic spray machine
Automatic control and recording of negative/anode fuel
flow, humidity, and temperature parameters
Water temperature control
Nitrogen purging
Air pressure gas fuel back pressure, heating, humidification
Fuel cell polarization curve recording
Fuel cell voltage inspection and recording
Fuel cell temperature monitoring and recording
Load safety protection
Water circulation and cooling
(The optional Single battery test, The optional function, Methanol fuel cell testing)
System number
ALXC_1800(manual version)
ALX_1800(Automatic version)
Product Parameters
Type test Water-cooled hydrogen fuel cell, |
air-cooled hydrogen fuel cell |
Maximum test power 1800W |
Power supply 220VAC |
Test current range 0~150A |
Test voltage range 0~60v |
Resolution of current 1mA/10mA |
Resolution of voltage 0.1mV1mV |
Hydrogen flow control Mass flow meter |
Airflow control Mass flow meter |
Nitrogen control Rotor flowmeter |
Anode/cathode accelerator temperature 0~90°C |
Temperature change setting 3°C/min |
Temperature error 0.5°C |
Humidity control precision ±2°C |
Data reading speed 0.1s |