Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane

Product Details
Customization: Available
Type: Ionite Membrane
Membrane Type: Pem
Still deciding? Get samples of US$ 80/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
101~500 square meters
  • Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane
  • Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane
  • Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane
  • Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane
  • Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane
  • Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane
Find Similar Products

Basic Info.

Model NO.
T-N-211
Raw Material
Resin
Transport Package
Carton Packing
Specification
1 Square meter
Trademark
Thinkru
Origin
China
HS Code
3921909001
Production Capacity
100000

Product Description

ePTFE (expanded polytetrafluoroethylene) microporous reinforcing material was added to the traditional proton exchange membrane, which has the characteristics of high strength, high conductivity and low ion permeability.


1.Thickness and Basis Weight Properties
Membrane Type Thickness(microns) (µm) Weight(g/m2)
T-N-3010 12 23.5
T-N-3015 15 29.5
T-N-211 25 50.0
T-N-212 51 102.0

2.PhysicalandOtherProperties
Physical and OtherProperties Index Parameters Test Method
  T-N-3010 T-N-3015 T-N-211/212  
Tensile Test (23°C, 50%RH) MD /TD MD /TD    
Tensile Strength(MPa) ≥32 ≥30 ≥28 /28 GB/T20042.3-2022
Tensile Modulu(MPa) ≥400 ≥350 ≥400 / 400 GB/T20042.3-2022
Elongation at break(%) ≥150 ≥180  ≥180 ≥100 / 120 GB/T20042.3-2022
Specific Gravity 1.97 1.97 1.97 -
Other Properties Index Parameters Test Method
2 Conductivity(S/cm) ≥0.100 ≥0.1100 ≥0.100 GB/T20042.3-2022
3 Hyrogen Crossovercm3·cm/(cm2.so.1MPa) <5.00×10- 8 <4.50×10-8   GB/T20042.3-2022
Hydrogen Crossover Current (mA/cm2) <2.0 <2.0    

3.Hydrolytic Properties
Hydrolytic Properties Index Parameters Test Method
5 Water Content(%) 10.0±3.0 10.0±3.0 10.0±3.0 GB/T 20042.3-2022
6 Water Uptake(%) 50.0±5.0 50.0±5.0 50.0±5.0 GB/T 20042.3-2022
from50% RH, 23ºCtowatersoaked,23ºC ≤ 10 ≤ 15 ≤ 10 GB/T 20042.3-2022
From 50% RH,23ºCtowatersoaked 100ºC ≤ 30 ≤ 40 ≤ 30 GB/T 20042.3-2022
Linear expansion,% increase(23°C, 50%RH) MD / TD MD / TD    
from50% RH, 23ºCtowatersoaked,23ºC ≤3 / ≤4 ≤4 / ≤7 ≤4 GB/T 20042.3-2022
From 50% RH,23ºCtowatersoaked 100ºC ≤ 5/ ≤5 ≤ 7 / ≤7 ≤20 GB/T 20042.3-2022
1 Measurements taken with membrane conditioned to 23C,50% RH.
2 Conductivity measurements a 80 'C, 90% RH.
3 Hydrogencrosso, 1er measured at 23ºC, 50%RH4 Hydrogen crossover Current measured in MEA on H2, 80C fully humidified gases
4 Water content of membrane conditioned to 23C and 50% RH (dry weight basis).
5
Water uptake from dry membrane to conditioned in water at 100 'C for 1 hour (dryweight basis).
Proton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange MembraneProton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange MembraneProton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange MembraneProton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange MembraneProton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange MembraneProton Exchange Membrane for Hydrogen Fuel Cells or Electrolyzer Ion Exchange Membrane





 